The Cable Commandor Model A7 Cable Locator Instruction Manual
The Model A 7 Cable Commander locator is designed for locating cables and pipes. It can be used to trace the exact route, position, and depth of a cable or pipe. The Model I.e. 49 or I.C. 56 Inductive Coupler is used to isolate a line from other utilities even though they are sharing a common ground. The Sewer Snooper or Mini-Snooper is used for locating non-metallic pipe and duct. These accessories are covered in this manual. See the Table of Contents for page number.
BATTERY TEST
RECEIVER: The receiver must be turned on to test the battery. Signal being received by the receiver will work the receiver battery as it is worked in normal operation, thus, the transmitter should also be turned on and the receiver Sensitivity control turned up when testing the receiver battery. Push the Battery Test switch for a battery voltage indication on the meter. Any meter reading in the Batt. OK scale indicates a good battery. A meter reading below the Batt. OK scale indicates the battery is low and should be replaced with an Eveready #216 or 9 volt equivalent.
Note: A safety check of the receiver battery is built in if the loudspeaker is being used. If the receiver audio and meter pulsates when a very low sensitivity setting is used, and the receiver is picking up signal from the transmitter. replace the receiver battery. A battery test will indicate a low battery.
Get pdf The Cable Commandor Model A7 Cable Locator Instruction Manual