Evaluation Kits EVA 100 and EVA 105 User Manual

Evaluation Kits EVA 100 and EVA 105 User Manual

EVA 100 and EVA 105 are evaluation kits to support the development of applications based on the EnOcean RCM receiver modules and the TCM transceiver modules. The kits support a quickly evaluation of all RCM receiver operation modes as well as a quite easy setting-up operation of the receiver side when EnOcean transmitter modules are evaluated.

PTM Push-Button Powered Transmitter
• The PTM radio transmitter modules from EnOcean enable the implementation of wireless remote controls without batteries. Power supply is provided by a built-in pressure energy converter.
• Key applications are on-wall mountable flat rocker switches or handheld remote controls.

STM 110 Solar Powered Transmitter
• The extremely power saving RF transmitter module STM 110 of EnOcean enables the realization of wireless and maintenance free sensors.
• Power supply is provided by a small solar cell. An integrated energy store allows unrestricted functionality for several days in total darkness.
• Three 8 bit A/D converter inputs and 4 digital inputs facilitate multifunctional detector systems, based on application specific passive sensing components. This allows easily and comfortable monitoring of position, temperature, illumination, pressure, etc. - or simply supervising voltages or currents.

Get pdf Evaluation Kits EVA 100 and EVA 105 User Manual

ATT77025/7027 Programmer’s User Manual

ATT77025/7027 Programmer’s User Manual

ATT7025/7027 programmer is used to load a program in the memory of ATT702X. It uses another ATT7025 (Host MCU) which communicates with PC and target MCU. The PC transfers the program code and corresponding checksum to a flash chip connected with host MCU through serial port. User can start programming by clicking the button on PC or the red button on programmer board (without PC). The programmer will verify after finishing programming.

To install the ATT7025/7027 programmer hardware:
(1) Connect the programmer to the serial port of PC using RS232 interface cable.
(2) Connect an external power supply to the programmer. The voltage of the power supply must be between 9V and 15V.

Software Description
(1) Run OnePortPro.exe
(2) The main window is shown below:
1) OpenPort Open the serial port of PC
2) Openfile Open Intel hex file and and display program code in program buffer
3) FlashErase Erase 64K flash chip connected to host MCU
4) FlashWritten Transfer program code to the 64K flash chip connected to host MCU and calculate the checksum displayed in edit box “Checksum1”.
5) GetChecksum Read back the program code loaded to 64K flash chip and calculate another checksum displayed in edit box “Checksum2”. If the data in “Checksum1” is the same as the data in “Checksum2”, that indicates the program code loaded in 64K flash chip is correct.
6) TargetErase Erase the target chip (need to be programmed) which user puts in the socket
7) PFPM Program the code in 64K flash chip into the target chip’s flash memory

Get pdf ATT77025/7027 Programmer’s User Manual

TELTONIKA ModemCOM/G10 (CM100) User Manual

TELTONIKA ModemCOM/G10 (CM100) User Manual

The PC and power supply source, to which the device “ModemCOM-TM2” is connected should satisfy LST EN 60950-1 standards. The device can be used with the first (Personal Computer) or the second (Notebook) computer safety class. In the installation place and supply circuits the protective devices should be tooled up (bipolar release device) which will protect the device from short-circuit and grounding troubles (Picture 1.1). The power of the release device should satisfy the power of connected to it devices. The interstice between release contacts should not be less than 3mm. The power supply network should be installed near device on easily accessible place.

Full disconnection of the device is performed by pulling out the constant current DC plug from the device. Data transfer cable for connection to another device must not be shorter than 2 meters.
Maintenance of the device:
If the device starts working faulty only qualified personnel may repair this product. We recommend dismantling the device and forwarding it tit repair center or to manufacturers. No exchangeable parts in the device.

This document will provide you with the instructions how to install and use ModemCOM/G10“ and its software. „ModemCOM/G10“ is a device designed for data transmission via GSM Network. The design of this modem enables the connection to your PC through COM interface. „ModemCOM/G10“ supports the following data-bearers: GPRS, CSD, CSF and SMS.

Get pdf TELTONIKA ModemCOM/G10 (CM100) User Manual

PLI-2030 200Mbps HomePlug AV Ethernet Bridge User Manual

PLI-2030 200Mbps HomePlug AV Ethernet Bridge User Manual

HomePlug powerline is an excellent solution that can be used to extend your network. In the home or small office building, use HomePlug Ethernet Bridge Adapters to link multiple locations without the need to run Ethernet cable. Combined with a broadband DSL/Cable connection, every room with electrical power outlets will have easy access to high-speed Internet connection.

200Mbps HomePlug AV Ethernet Bridge allows you to connect any device which has an Ethernet port to a Power-line network. In operation, the 200Mbps HomePlug AV Ethernet Bridge is completely transparent, and simply passes data between the Ethernet port and the Powerline network. The Powerline data transfer rate can be reached up to 200Mbps. Any device may be connected to the 200Mbps HomePlug Ethernet Bridge’s Ethernet port, but a Windows PC must be used for configuration.

Setup
Configuration requires the use of Windows PC. Once configured, any device may be connected to the 200Mbps HomePlug AV Ethernet Bridge’s Ethernet port. To perform configuration, follow the procedures list below.
1. Connect a standard LAN cable from the 200Mbps HomePlug AV Ethernet Bridge’s Ethernet port to your PC.
2. Plug the 200Mbps HomePlug AV Ethernet Bridge into a power outlet.
3. Wait a few seconds for startup to be completed, and then check the LEDs
• The Power LED should be ON.
• The HomePlug LED will be ON if other HomePlug devices are detected, otherwise it will be OFF.
• The Ethernet LED should be ON.
4. Insert the supplied CD-ROM into your Windows PC, and wait for it to start, select “Utility” from the autorun screen. If it does not start automatically, locate and run SETUP.EXE.
5. Follow the prompts to install the PLI-2030 utility.
6. Microsoft .NET Framework 1.1 is needed for installing PLI-2030 utility. The wizard will check automatically whether the Microsoft .NET Framework 1.1 was installed on your PC or not. If not, the wizard will pop up a message box. Click OK to install Microsoft .NET Framework 1.1 first

Get pdf PLI-2030 200Mbps HomePlug AV Ethernet Bridge User Manual

Sprintwealth