Bipolar/Monopolar Temperature Controller Model TC-202A User’s Manual

Bipolar/Monopolar Temperature Controller Model TC-202A User’s Manual

The Bipolar/Monopolar Temperature Controller (Model TC-202A) is designed to be used with several micro-incubators supplied by Harvard Apparatus Inc.These models include the Open Perfusion Micro-Incubator (Model PDMI-2), Patch Slice Micro-Incubator (Model PSMI),Leiden Static Micro-Incubator (Model LU-CB1) Leiden Closed Perfusion Micro-Incubator (Model LU-CPC-CEH) and Brain/Tissue Slice System (Model BSC-BU).

A micro-incubation system from Harvard Apparatus consists of the Temperature Controller (TC-202A),a micro-incubator (one of the above) of choice,a 35 mm plastic Petri dish or reusable cover slip dish (LU-CSD, MSC-TD or MSC-PTD) and an associated pumping system.Such a system allows complete environmental conditioning along with excellent micro-mechanical access for electrodes or micropipettes, all with optimum optical access.

A proportional temperature controller is basically a source of electric current whose magnitude is determined by comparing a desired target temperature with its current value. The TC-202A’s output is proportional to the difference in temperature between the desired and the current value. This type of system avoids the electrical noise of suddenly turning current on and off, unlike less expensive controllers. When using the TC-202A in the Biphasic mode, the current will spontaneously reverse direction when the current temperature is too high; in short,it can also cool when used with Peltier elements.(PDMI-2/PSMI)

Get pdf Bipolar/Monopolar Temperature Controller Model TC-202A User’s Manual

GE4000 User Manual

GE4000 User Manual

The GE4000 series of cameras are sensitive, 5 frames per second, 11 megapixel, Gigabit Ethernet cameras based on the Kodak KAI-11002 CCD sensor.

Supported Features
Imaging Modes
free-running, external trigger, fixed rate, software trigger
Fixed Rate Control
0.001 fps to maximum frame rate
External Trigger Delay 0 to 60 seconds in 1 microsecond increments
External Trigger Event rising edge, falling edge, any edge, level high, level low
Exposure Time
140 microseconds to 60 seconds in 1 microsecond increments
Gain
0 to 25dB
Region of Interest (ROI) independent x and y control with 1 pixel resolution***
Horizontal Binning
1 to 8 pixels
Vertical Binning
1 to full resolution of sensor***
Pixel Formats
Mono8, Mono16*, Bayer8, Bayer16
Sync Out Modes
trigger ready, trigger input, exposing, readout, imaging, strobe, GPO

The General Purpose I/O port uses a Hirose HR10A-10R-12SB connector on the camera side. The mating cable connector is Hirose HR10A-10P-12P. This connector can be purchased from Prosilica or from http://www.digikey.com.
See Addendum for more detail.
DO NOT EXCEED 5.5V ON SIGNAL INPUTS.
All inputs and outputs are galvanically isolated from the internal camera circuitry.

TRIGGER INPUT
This input signal allows the camera to be synchronized to some external event. The camera can be programmed to trigger on the rising or falling edge of this signal. The camera can also be programmed to capture an image at some programmable delay time after the trigger event.

Get pdf GE4000 User Manual

ST-402 Operating Manual

ST-402 Operating Manual

Congratulations and thank you for buying one of our ST-402 cooled CCD cameras. The ST-402 has the following features:
• Uses Kodak’s microlensed, blue enhanced KAF-0402ME CCD with 765 x 510 9-micron square pixels.
• 16-bit A/D converter with correlated double sampling running at 1.8 megahertz.
• Temperature regulated Thermo-Electric (TE) cooling with 25C delta for reduction in CCD dark current.
• Single board, small, compact design with internal shutter allowing exposures down to 40 milliseconds that makes taking dark frames a trivial task.
• USB 2 interface yielding up to 1.2 megapixels per second download rates but full backward compatibility with USB 1.1 computers at 400 kilopixels per second.
• Input power requirements of 10.0 – 14.5 Volts DC at 1 Amp through the new center-positive locking power jack.
• Telescope interface with four optically isolated normally open signals on the industry standard RJ-11 jack.
• T-Thread based mechanical interface that supports a variety of nosepieces and adapters.
• Optional 4-position filter wheel with parfocal Red, Green, Blue and Clear filters.
• Powerful yet intuitive CCDOps software for image acquisition and processing.

Getting Started
In addition to this truly fine Operating Manual, the ST-402 package includes the following items:
ST-402 Camera – The camera body is 4 x 5 x 2 inches with a T-Thread adapter on the front cover. 1 ¼ Inch T-Thread Nosepiece – This screws into the front of the camera for telescope work and includes a soft rubber cap for keeping out the dust when not in use. Optional 2 Inch Nosepiece and Visual Back adapters are available from SBIG. In addition a screw-in T-to-C adapter is available for use with C-Mount camera lenses or C-Mount adapters.

Get pdf ST-402 Operating Manual

Home Theater Plus URC8780 User Manual

Home Theater Plus URC8780 User Manual

The illustration below and the chart describe the features and the functions of the HOME THEATER PLUS keypad. The following keys will always have the same function, regardless of which component you are controlling. For an explanation of what each key does by component type, please use the index at the rear of the manual.

Feature Function
The SETUP key is used to access the menu and program your HOME THEATER PLUS.
The TV, VCR, CBL/SAT, DVD/LD, TUNER, , CD, AMP and AUX1 keys are used to select the home entertainment component you want to control. If your component does not respond when you press a key on the remote control, press the TV, VCR, DVD/LD, CBL/SAT, TUNER, AMP, CD, or AUX1 key to tell the remote control which component you would like to operate.
The ESC (Escape) key is used to exit the LCD Screen menu.
The LITE key is used to turn ON and OFF the HOME THREATER PLUS’s backlit keypad and LCD screen. Press the LITE key once to turn ON the back light. The HOME THREATER PLUS’s backlight will stay on for 5 seconds after the last key press and re-activates with the press of a key. To de-activate the backlight, press the LITE key again.
The POWER key controls power ON and OFF.
The VOL + (Volume Up), VOL – (Volume Down) and
MUTE keys control the volume the same as the Volume Up and Down and Mute keys on your original remote.
The CH + (Channel Up) and CH – (Channel Down) keys change channels the same as the Channel Up and Down keys on your original remote.
The MACRO key memorize up to 15 keystrokes that can be accessed in sequence at the press of a single key. These keys are not mode specific. The SHIFT key accesses advanced features that are mapped under the following keys: MENU, MUTE, PREV CH, PIP, REW, PLAY, FF, STOP, and PAUSE. The 1L ~ 4L keys are used for learning new features onto the HOME THREATER PLUS.

Get pdf Home Theater Pluc URC8780 User Manual

Sprintwealth