UniClamp Instructions

UniClamp Instructions

Here we’ll demonstrate, using our Nikon CP 950. The purpose of the photo is to show the Camera Tripod Mount Platform attached, and alignment of the Center Line of the UniClamp with respect to the center line of the Camera Lens. With this type of camera, the lens is fixed (doesn’t move in or out) and we’re going to continue to bring the UniClamp closer until they actually meet. Please remember that no locking Thumb Screws are tight at this point, if they were, you could not make the adjustments needed and possibly damage the camera.

In this photo, the final adjustment is made. This adjustment is centering the camera lens in reference to the center of the UniClamp Adapter. Don’t become frustrated, it takes a little practice because you are moving in 3 directions at the same time. Once you feel you have proper alignment, now tighten the Thumb Screws in the following order. Camera Tripod Mount Platform, The Thumb Screw on the Camera Tripod Mount Platform, and then the Thumb Screw on the UniClamp Adapter (Do Not Disturb the 3 Thumb Screws on Body of the UniClamp Adapter). During this process, things can have a tendency to move, so you will need to correct for those adjustments, but make them from a loose perspective as trying to force things while they are tight could cause damage to the Adapter and Camera (meaning, if you have loosen the Thumb Screws that you just tightened, do so).

Now replace assembly on Microscope Eyepiece. Being careful not to crash the Microscope Eyepiece into the Camera Lens and tighten the loosened Thumb Screw.

Get pdf UniClamp Instructions

Keeler Slit Lamp Instructions

Keeler Slit Lamp Instructions

Keeler Slit Lamps are instruments designed to give a very high level of performance. In order to ensure you gain the maximum benefits from your Keeler Slit Lamp we suggest that you read this instruction manual carefully before assembly or use. Please be sure to check all warning or rating labels on your Slit Lamp.

Main features of Keeler Slit Lamps
• Keeler Slit Lamps are combination of outstanding optical performance combined with elegant yet functional design.
• Quality optics to reduce eye fatigue and to ensure clear crisp images.
• X-Y-Z base with single joystick control.
• Stereo microscope body with magnifications of x10 and x16, x6 to x40 or x6 to x33 zoom depending on model.
• Accessories for attaching digital cameras, cctv cameras, teaching tube. Tonometers.
• Tilt facility 5°, 10°, 15°, 20° (Tower illumination systems only).
• Optional filters, diffusers.
• Optional measuring eyepieces.

Get pdf Keeler Slit Lamp Instructions

Charge Preamplifiers ICP 100/110/120 Operators Manual

Charge Preamplifiers ICP 100/110/120 Operators Manual

The Charge Preamplifiers ICP1×0 are used for piezoelectric transducers with charge output. These types of transducers are frequently given preference over ICP® compatible transducers because of their smaller dimensions and their higher dynamic range. Sometimes high temperature at the measuring point does not allow electronic circuits near to this place. The Charge Preamplifiers ICP1×0 have an ICP® compatible voltage output with low impedance. The output signal can be transmitted over long distances using inexpensive coaxial cables. The ICP1×0 is supplied by constant current via the output cable. Therefore, a special cable for power supply is not required.

Function
The abbreviation ICP® means “Integrated Circuit Piezoelectric”. It has been established be- tween many other brand names as
industrial standard for piezoelectric transducers. The integrated circuit of the Charge Preamplifier transforms the charge signal of the piezo ceramics, with its very high impedance and high sensitivity against interference, into a voltage signal with low impedance. This signal may be transmitted and processed much easier than the high impedance charge signal.

The distinguishing feature of the integrated circuits for impedance transformation is, that power supply and measuring signal are transmitted via the same cable. Figure 1 shows the circuit diagram. For easy separation of the low impedance output signal from the power supply, the amplifier circuit is supplied with constant current. This constant current has to be fed into the measuring line.

Get pdf Charge Preamplifiers ICP 100/110/120 Operators Manual

TEW-410APB Wireless 802.11g AP User’s Manual

TEW-410APB Wireless 802.11g AP User’s Manual

The package you have received should contain the following items:
- AP Wireless 802.11g AP
- User Guide
- Power Supply / Cord
- Ethernet Cable

Your Wireless AP should be placed in a safe and secure location. To ensure proper operation, please keep the unit away from water and other damaging elements. Please read the user manual thoroughly before you install the device. The device should only be repaired by authorized and qualified personnel.

- Please do not try to open or repair the device yourself.
- Do not place the device in a damp or humid location, i.e. a bathroom.
- The device should be placed in a sheltered and non-slip location within a temperature range of +5 to +40 Celsius degree.
- Please do not expose the device to direct sunlight or other heat sources. The housing and electronic components may be damaged by direct sunlight or heat sources.

Get TEW-410APB Wireless 802.11g AP User’s Manual